Near-infrared imaging & spectroscopy

Connect confocal imaging, single-photon detection and time measurements around the fluorescence signal from your sample, for life science and materials research.

Near-infrared imaging & spectroscopy

What would you like to measure?

Twelve typical research directions across four fields: life-science imaging, biomedical probes, materials luminescence & spectroscopy, and quantum & low-dimensional materials. Each places different demands on excitation and emission bands, spatial and temporal resolution and signal level — use them to plan a Qumi configuration and related modules.

Not listed here? Tell us about your experiment

Connect the measurement chain

  1. 01Excitation & sample

    Near-infrared excitation is focused onto in-vivo, tissue-section or material samples.

  2. 02Collection & scanning

    Galvo scanning and confocal collection capture weak fluorescence point by point.

  3. 03Photon detection

    SNSPDs receive near-infrared photons with high efficiency and low dark counts.

  4. 04Imaging or timing

    Reconstruct 2D / 3D images, or run time-resolved analysis such as FLIM and TRPL.

An indicative experimental workflow. Modules and compatibility are confirmed for each configuration.

Qumi series

Explore single-photon confocal imaging and related measurement configurations.

SNSPD detection

Assess detection options against emission band and background signal.

Timing & optoelectronics

Select time-correlated single-photon counting and accessories as required.

Capabilities & key specifications

Qumi superconducting-detection laser scanning confocal microscope

Single-photon confocal imaging with superconducting detection

Qumi-2000 detects fluorescence with superconducting nanowire single-photon detectors, offering higher detection efficiency (peak quantum efficiency >90% at 1550 nm), one to two orders of magnitude lower noise and lower timing jitter.

Peak quantum efficiency
>90%at 1550 nm
Detection range
400–2500 nmvisible to short-wave infrared
Time resolution
50–100 psfor lifetime and time-resolved work
Noise level
10 Hzat 90% efficiency; 1–2 orders lower

Qumi at a glance

Tell us about your experiment.

Share your sample, measurement goals and existing equipment so we can discuss a suitable configuration.

  • Sample and research objective
  • Excitation and emission bands
  • Imaging, spectral or lifetime measurements
  • Existing microscope and synchronization interfaces